Architecture firms are a species of their own in the SMB market. Project files range from 20 KB detail views to 8 GB point clouds, with Revit models, IFC exchange files, Archicad projects, PDF plans, construction site photos and, at the end, renderings for the client in between. What every firm shares, whether five or fifty people: when the file server stutters, the whole design process stutters. And when Revit takes 90 seconds to save, nobody saves “in between” any more. Then the afternoon is gone, not just the file.
This article is the practical companion to our earlier primer TrueNAS for Architecture Firms: Plans, Renderings, Versioning. That piece covered file sizes, HOAI retention and the idea of snapshots as a plan history. Here we focus on the underlying tech: how do we build CAD storage on TrueNAS that handles Autodesk products, Archicad, rendering workstations and up to 25 concurrent accesses without SMB stuttering?
What CAD workloads actually ask of your storage
Before we stack hardware, it is worth being honest about the load. CAD and BIM workloads look different on disk than many datasheets suggest.
- Many small random reads when opening Revit and Archicad projects. Internally these projects are hundreds of references, family files and helper files. Each is its own access.
- Large sequential writes when saving rendering outputs, animated camera paths and exported visualisations.
- Mixed workload on IFC export and when merging partial models from several specialist planners. The data stream alternates with metadata operations.
- Metadata pressure from the typical project folder structure: deep directory trees, many small files and search operations across project and template directories.
- Concurrent access on the same project folders, often with AutoCAD xref references or Revit central-model workflows.
Anyone who has seen an architecture firm without proper storage knows the pattern: raw throughput is not the problem. Latency on small files and responsiveness under concurrent access are. We address both with the right ZFS and SMB configuration.
TrueNAS hardware for the architecture firm: honestly sized
For a typical firm with 10 to 25 staff and an active project volume of 3 to 10 TB, we most often build the environment on a TrueNAS Enterprise M30. Smaller firms are usually fine with a Mini R; larger practices or ones running additional VM workloads step up to the M40. Both M models are our current recommendation — the older M50 and M60 series are EOL and no longer our pick for new projects.
We size each setup individually. If you need a starting point, the TrueNAS configurator helps, and as an authorised iXsystems partner we handle hardware procurement with manufacturer warranty. Ongoing technical support for live systems is bundled in TrueNAS Support.
What a CAD setup typically contains:
- Mirrored NVMe as boot pool (TrueNAS itself, config, SMB service).
- Data pool from HDD mirror vdevs (not RAIDZ). Mirror vdevs deliver much better random IO and rebuild gentler — two things that matter more for CAD projects than squeezing out the last TB of capacity.
- Metadata vdev from at least two mirrored NVMe SSDs. This is the single biggest lever for CAD workloads: directory listings, permissions and small metadata live on flash, not on spinning disks.
- Plenty of RAM as ARC, so hot projects live entirely in cache.
- Second 10 GbE NIC for SMB Multichannel, cleanly separated on the switch.
As the operating system we run TrueNAS 25.10 “Goldeye” — the current stable release. TrueNAS 27 GA ships in early December 2026. We test the new release extensively in-house before letting it land in customer production. We will not move architecture firms to it until it has a few point releases behind it.
SMB Multichannel and 10 GbE: the difference you feel
Modern SMB (SMB 3.x) can use multiple network paths at once. A workstation with two NICs, or a workstation plus a server with two NICs, then speak over two parallel TCP connections. For sequential rendering writes and for opening large Revit projects, that is the difference between “noticeably fast” and “time for a coffee”.
We deploy Multichannel in nearly every CAD environment. The technical configuration is covered in our deep-dive TrueNAS SMB Multichannel with 10 GbE done right. Two points matter especially in architecture firms:
- Rendering workstations first. The machines doing 4K or 8K rendering get 10 GbE and the second NIC first. CAD seats using “just” AutoCAD or Archicad can often live with 1 GbE a while longer, as long as the server and switch sit on 10 GbE.
- Check the switch backplane. A 10 GbE switch with an undersized backplane throws away all Multichannel benefit. For a small firm an 8- or 16-port 10 GbE switch at full line rate is usually enough.
In addition to Multichannel we enable SMB encryption with AES-128-GMAC (not the older CCM variant, see TrueNAS SMB Protocol Security and AES). AES-128-GMAC is the modern standard, has negligible performance cost on current hardware and protects SMB traffic against internal eavesdroppers — for example compromised clients on the same LAN.
Project folders, snapshots and an honest return to “last Wednesday”
An architecture firm works in project folders, not in a database. Each engagement has a project number, a folder with CAD, model, exchange and rendering subfolders, inputs from specialist planners and, at the end, the delivery documents. That project folder lives on an SMB share and is the central working directory for everyone on the team.
For the snapshot strategy we split the shares into datasets — one per project or per project group, depending on firm size. That lets us tune snapshots per project:
- Every 15 minutes during office hours, with short retention (four hours).
- Hourly with 48-hour retention.
- Daily with 30-day retention.
- Weekly with six months of retention.
- Monthly with multi-year retention, aligned with HOAI and building-law obligations.
ZFS snapshots are cheap to keep and let you ask the quiet question: “What did the plan look like at midday on Wednesday, before the structural engineer re-planned the load path?” Two clicks in the Windows “Previous Versions” dialog and the answer is on the table. For rendering workstations on macOS the same recovery works through the TrueNAS web UI.
Important: snapshots do not replace document management or a contract archive. They are a technical safety net, not the project record. For durable approvals, release stamps or digital signatures, you still need a DMS, a dedicated project room, or at least a clear manual folder structure with approval conventions.
Autodesk, Archicad, Vectorworks: lessons from the field
We regularly hear the question whether TrueNAS is “Autodesk compatible”. The honest answer: Autodesk, Archicad and Vectorworks speak SMB — and TrueNAS delivers SMB. More important than vendor logos are three practical details from experience:
- No duplicate user and group IDs. When Windows and macOS clients mix, the integration with Active Directory or a central identity provider should be clean. Local users on the NAS are a starting point, not a destination.
- ACLs over SMB, not POSIX. For CAD projects we want to use the NTFS-style ACLs over SMB so project leads can control, per project, who can write and who can only read. TrueNAS supports this from the web UI.
- File-name policy. Umlauts and special characters in filenames are fine on Windows, but can create friction in mixed macOS-Windows setups. We recommend an honest internal file-name convention — not because of TrueNAS, but because of the OS mix and external files from partners.
For environments with heavy rendering load, we sometimes add a rendering scratch space on a dedicated workstation or rendering node that writes the final result back to TrueNAS. That takes pressure off the main system during long renders.
Backup and offsite: the second location is part of the solution
An architecture firm that loses its project data loses more than working hours — it loses parts of its contractual delivery. So the CAD storage always comes with a backup concept that includes an offsite leg. Two standard building blocks:
- ZFS replication to a second TrueNAS system at another location — the owner’s home office, a second branch, or a hosted rack at DATAZONE.
- Object-lock target in an S3-compatible cloud store for the most critical project data as a third copy. We covered this in detail in our article on immutable backups with TrueNAS and Veeam.
For ongoing operations we offer managed services for architecture firms with a fixed monthly budget and clear response times. The decision stays with the customer — we document, explain, accompany.
FAQ: TrueNAS, CAD and rendering in the architecture firm
How big does a TrueNAS have to be for a 15-person architecture firm?
A 15-person firm commonly produces 3 to 6 TB per active year. With 10 years of HOAI retention plus the live working set, we are talking about 40 to 80 TB usable plus backup capacity. A TrueNAS M30 with properly sized mirror vdevs and a metadata vdev usually covers it.
Is 1 GbE really no longer enough?
For pure CAD work with AutoCAD or Archicad, 1 GbE is often technically fine — right up to the moment someone opens a big Revit central model or a rendering gets written. Then you feel the difference. For new environments we recommend 10 GbE at the server and at least on the rendering workstations.
What about SMB Multichannel on macOS?
macOS supports SMB Multichannel reliably from Ventura onwards, with minor caveats. In pure Mac environments we enable it but document the specifics for support. In mixed environments the benefit is often larger on the Windows workstations, because that is where the rendering load sits.
Do I really need a metadata vdev?
For a pure backup or archive NAS: no. For CAD workloads with many small files, deep directory trees and frequent searches: almost always yes. The metadata vdev is one of the cheapest performance levers in ZFS.
Do snapshots replace my DMS?
No. Snapshots are a technical safety net and answer the question “what did it look like two hours ago”. A DMS answers “who approved which version and when”. Different purposes, complementary.
When do we move to TrueNAS 27?
TrueNAS 25.10 “Goldeye” is the current stable release for production. TrueNAS 27 GA ships in early December 2026. We test 27 in-house, gather experience and recommend the move for production architecture firms only once a few point releases are behind 27. Conservative, but with live project data that is our stance.
More on these topics:
More articles
Measuring TrueNAS Performance with fio and iozone: Methodology, Pitfalls and How to Get Honest Numbers
Measuring TrueNAS performance in practice: how to set up fio and iozone sensibly, why the ARC cache distorts almost every result, and what benchmarks really tell you and what they do not.
TrueNAS with Let's Encrypt: Automating SSL Certificates for UI, WebShare, and Apps
TrueNAS Let's Encrypt in practice: ACME setup in 25.10 Goldeye, DNS-01 for wildcards, assignment to UI, WebShare and Apps, auto-renewal without downtime.
GDPR Art. 9 in Medical Practices: How TrueNAS Protects Special Categories of Personal Data
GDPR Art. 9 in medical practices in detail: health data on TrueNAS with encryption, audit logging and a defensible retention concept per Section 630f BGB.